China Ends R22 VRF Production on 1 January 2027: What Changes
ঘটনা
আমাদের সাথে যোগাযোগ করুন
Miss. LISA
86--19068528348
এখনই যোগাযোগ করুন

China Ends R22 VRF Production on 1 January 2027: What Changes

2026-11-18
Latest company news about China Ends R22 VRF Production on 1 January 2027: What Changes

China will stop producing R22-based VRF air conditioning and heat pump units from 1 January 2027.

 



The rule covers new production only. Installed systems stay legal, service gas remains available under quota, and R22 chillers have another three years. What changes is narrower and more consequential than a ban: the last low-cost refrigerant option in the world's largest VRF market closes, and every quotation from that date has to name a refrigerant.


The Announcement

 

China's Ministry of Ecology and Environment published Announcement No. 42 of 2026 on 2 September 2026, following a public consultation opened in April.

 

From 1 January 2027, no new VRF air conditioning or heat pump unit may be produced in China with HCFC-22 as its refrigerant. The product scope is defined by four standards: GB/T 18837 for VRF units, GB/T 25857 for low ambient air source VRF heat pumps, JB/T 11966 for air source VRF heat pump water heaters, and JB/T 14064 for photovoltaic-driven VRF units.

 

The legal basis is China's obligations under the Montreal Protocol and the national plan for phasing out ozone-depleting substances.


At a Glance

 

• Effective date: 1 January 2027, which is 44 days from the date of this article

• Covers: new production of R22 VRF and VRF heat pump units in China

• Does not cover: units already installed, service refrigerant, or R22 chillers

• Share of VRF refrigerant affected: approximately 15 tonnes, under 0.1 percent of the subsector total

• China's share of global VRF production and use: more than 60 percent 


What It Does Not Cover

 

Three exclusions matter more than the ban itself.

 

Installed equipment is unaffected. There is no recall, no retrofit mandate and no prohibition on operating an R22 system.

 

Service refrigerant remains available. R22 production continues within China's HCFC quota, which is being reduced in steps rather than switched off. The 2026 quota is 146,100 tonnes for production and 77,900 tonnes for domestic use, down 3,005 and 2,914 tonnes respectively from 2025. That gas is still legal for maintaining existing systems.

 

R22 chillers are not covered yet. Under the same national plan, production of HCFC-based industrial and commercial refrigeration and air conditioning equipment ends on 1 January 2030. Chiller buyers have three more years, which is not the same as three years of comfortable margin.


The Number That Reframes the Story

 

China produces and uses more than 60 percent of the world's VRF equipment, across more than 30 manufacturers. The subsector consumes over 20,000 tonnes of refrigerant a year, and almost all of it is already R410A, R32, R452B or R454B.

 

R22 in this subsector accounts for roughly 15 tonnes. That is under 0.1 percent of the total being phased out nationally.

 

So the announcement is not a market shock. It is a line drawn. The practical effect is that from January 2027, no Chinese supplier can offer an R22 VRF as a cheaper alternative, and buyers who still specify by price alone lose their floor.


Three Clocks, One Six-Year Window

 

Market

Instrument

Date

What changes

China

MEE Announcement No. 42 of 2026

1 Jan 2027

No new production of R22 VRF units

China

National ODS phase-out plan

1 Jan 2030

No new production of HCFC-based commercial refrigeration and AC equipment

EU

F-Gas Regulation (EU) 2024/573

1 Jan 2025

Single split systems under 3 kg charge with GWP of 750 or more prohibited

EU

F-Gas Regulation (EU) 2024/573

1 Jan 2027

Split air-to-water up to 12 kW with GWP of 150 or more prohibited; chillers above 12 kW with GWP of 750 or more prohibited

EU

F-Gas Regulation (EU) 2024/573

1 Jan 2029

Split air-to-air up to 12 kW with GWP of 150 or more prohibited; split systems above 12 kW with GWP of 750 or more prohibited

EU

F-Gas Regulation (EU) 2024/573

1 Jan 2033

Split systems above 12 kW with GWP of 150 or more prohibited

EU

F-Gas Regulation (EU) 2024/573

1 Jan 2035

All split systems up to 12 kW containing fluorinated gases prohibited

US

AIM Act, Technology Transitions

1 Jan 2025

Comfort cooling chillers limited to GWP of 700

US

AIM Act, Technology Transitions

1 Jan 2026

Residential and light commercial systems installed must be at or below GWP 700

US

AIM Act, Technology Transitions

1 Jan 2027

VRF systems installed must be at or below GWP 700

 

A system specified in 2027 and installed in 2028 will still be running in 2038. That is why the 2033 date belongs in a 2027 purchasing decision.


The 2033 Wall

 

Refrigerant

GWP (AR4)

Clears US 700

Clears EU 750

Clears EU 150

R22

1,810

No

No

No

R410A

2,088

No

No

No

R452B

676

Yes

Yes

No

R32

675

Yes

Yes

No

R454B

466

Yes

Yes

No

R290

3

Yes

Yes

Yes

 

R32 at 675 clears the US limit of 700, the EU limit of 750, and China's 2029 threshold. It is the most widely adopted single-component answer and it is a sound choice for most projects commissioned before 2030.

 

It does not clear 150.

 

Every mainstream HFC blend fails that line, because 150 is below the GWP of the refrigerants themselves. For VRF equipment above 12 kW in Europe, the options below 150 are effectively propane, at a GWP of 3. That brings charge limits, ventilation requirements, electrical classification and installer competence into the specification, and it is not a drop-in replacement for a conventional VRF.

 

The honest reading: R32 and R454B are bridges, not destinations. For projects with a design life past 2033 in Europe, the refrigerant strategy needs to be a decision now, not a deferral.


What Buyers Should Check

 

Get the refrigerant and GWP in writing on the quotation. Not in a brochure, not in a footnote. If it is not on the quote, it is not specified.

 

Match the model to the destination market, not to the price list. A unit compliant in Southeast Asia may not be compliant in the EU or the US, and the difference is not always visible on the nameplate.

 

Record the charge per circuit in kilograms. Charge drives safety class, leak-check obligations and, in the EU, whether the equipment can be placed on the market at all.

 

Ask about service gas and spares for the design life, not the warranty period. A five-year warranty on a twenty-year asset answers the wrong question.


About Henan Hongtai HVAC Equipment Co., Ltd.

 

Hongtai HVAC supplies VRF systems, air-cooled and water-cooled chillers, heat recovery ventilation units and rooftop packages to distributors and contractors in more than 80 countries. The company operates 12 automated production lines with annual capacity above 500,000 sets, and holds CE, Eurovent, TUV SUD, SASO, ESMA, GCC and ISO 9001, 14001 and 45001 certifications. Products are T3 rated for operation up to 55 degrees Celsius, and shipments are made FOB Ningbo and Shanghai.

 

For refrigerant and GWP confirmation on a specific model, contact our export team with the destination country and the capacity range.



পণ্য
খবর বিস্তারিত
China Ends R22 VRF Production on 1 January 2027: What Changes
2026-11-18
Latest company news about China Ends R22 VRF Production on 1 January 2027: What Changes

China will stop producing R22-based VRF air conditioning and heat pump units from 1 January 2027.

 



The rule covers new production only. Installed systems stay legal, service gas remains available under quota, and R22 chillers have another three years. What changes is narrower and more consequential than a ban: the last low-cost refrigerant option in the world's largest VRF market closes, and every quotation from that date has to name a refrigerant.


The Announcement

 

China's Ministry of Ecology and Environment published Announcement No. 42 of 2026 on 2 September 2026, following a public consultation opened in April.

 

From 1 January 2027, no new VRF air conditioning or heat pump unit may be produced in China with HCFC-22 as its refrigerant. The product scope is defined by four standards: GB/T 18837 for VRF units, GB/T 25857 for low ambient air source VRF heat pumps, JB/T 11966 for air source VRF heat pump water heaters, and JB/T 14064 for photovoltaic-driven VRF units.

 

The legal basis is China's obligations under the Montreal Protocol and the national plan for phasing out ozone-depleting substances.


At a Glance

 

• Effective date: 1 January 2027, which is 44 days from the date of this article

• Covers: new production of R22 VRF and VRF heat pump units in China

• Does not cover: units already installed, service refrigerant, or R22 chillers

• Share of VRF refrigerant affected: approximately 15 tonnes, under 0.1 percent of the subsector total

• China's share of global VRF production and use: more than 60 percent 


What It Does Not Cover

 

Three exclusions matter more than the ban itself.

 

Installed equipment is unaffected. There is no recall, no retrofit mandate and no prohibition on operating an R22 system.

 

Service refrigerant remains available. R22 production continues within China's HCFC quota, which is being reduced in steps rather than switched off. The 2026 quota is 146,100 tonnes for production and 77,900 tonnes for domestic use, down 3,005 and 2,914 tonnes respectively from 2025. That gas is still legal for maintaining existing systems.

 

R22 chillers are not covered yet. Under the same national plan, production of HCFC-based industrial and commercial refrigeration and air conditioning equipment ends on 1 January 2030. Chiller buyers have three more years, which is not the same as three years of comfortable margin.


The Number That Reframes the Story

 

China produces and uses more than 60 percent of the world's VRF equipment, across more than 30 manufacturers. The subsector consumes over 20,000 tonnes of refrigerant a year, and almost all of it is already R410A, R32, R452B or R454B.

 

R22 in this subsector accounts for roughly 15 tonnes. That is under 0.1 percent of the total being phased out nationally.

 

So the announcement is not a market shock. It is a line drawn. The practical effect is that from January 2027, no Chinese supplier can offer an R22 VRF as a cheaper alternative, and buyers who still specify by price alone lose their floor.


Three Clocks, One Six-Year Window

 

Market

Instrument

Date

What changes

China

MEE Announcement No. 42 of 2026

1 Jan 2027

No new production of R22 VRF units

China

National ODS phase-out plan

1 Jan 2030

No new production of HCFC-based commercial refrigeration and AC equipment

EU

F-Gas Regulation (EU) 2024/573

1 Jan 2025

Single split systems under 3 kg charge with GWP of 750 or more prohibited

EU

F-Gas Regulation (EU) 2024/573

1 Jan 2027

Split air-to-water up to 12 kW with GWP of 150 or more prohibited; chillers above 12 kW with GWP of 750 or more prohibited

EU

F-Gas Regulation (EU) 2024/573

1 Jan 2029

Split air-to-air up to 12 kW with GWP of 150 or more prohibited; split systems above 12 kW with GWP of 750 or more prohibited

EU

F-Gas Regulation (EU) 2024/573

1 Jan 2033

Split systems above 12 kW with GWP of 150 or more prohibited

EU

F-Gas Regulation (EU) 2024/573

1 Jan 2035

All split systems up to 12 kW containing fluorinated gases prohibited

US

AIM Act, Technology Transitions

1 Jan 2025

Comfort cooling chillers limited to GWP of 700

US

AIM Act, Technology Transitions

1 Jan 2026

Residential and light commercial systems installed must be at or below GWP 700

US

AIM Act, Technology Transitions

1 Jan 2027

VRF systems installed must be at or below GWP 700

 

A system specified in 2027 and installed in 2028 will still be running in 2038. That is why the 2033 date belongs in a 2027 purchasing decision.


The 2033 Wall

 

Refrigerant

GWP (AR4)

Clears US 700

Clears EU 750

Clears EU 150

R22

1,810

No

No

No

R410A

2,088

No

No

No

R452B

676

Yes

Yes

No

R32

675

Yes

Yes

No

R454B

466

Yes

Yes

No

R290

3

Yes

Yes

Yes

 

R32 at 675 clears the US limit of 700, the EU limit of 750, and China's 2029 threshold. It is the most widely adopted single-component answer and it is a sound choice for most projects commissioned before 2030.

 

It does not clear 150.

 

Every mainstream HFC blend fails that line, because 150 is below the GWP of the refrigerants themselves. For VRF equipment above 12 kW in Europe, the options below 150 are effectively propane, at a GWP of 3. That brings charge limits, ventilation requirements, electrical classification and installer competence into the specification, and it is not a drop-in replacement for a conventional VRF.

 

The honest reading: R32 and R454B are bridges, not destinations. For projects with a design life past 2033 in Europe, the refrigerant strategy needs to be a decision now, not a deferral.


What Buyers Should Check

 

Get the refrigerant and GWP in writing on the quotation. Not in a brochure, not in a footnote. If it is not on the quote, it is not specified.

 

Match the model to the destination market, not to the price list. A unit compliant in Southeast Asia may not be compliant in the EU or the US, and the difference is not always visible on the nameplate.

 

Record the charge per circuit in kilograms. Charge drives safety class, leak-check obligations and, in the EU, whether the equipment can be placed on the market at all.

 

Ask about service gas and spares for the design life, not the warranty period. A five-year warranty on a twenty-year asset answers the wrong question.


About Henan Hongtai HVAC Equipment Co., Ltd.

 

Hongtai HVAC supplies VRF systems, air-cooled and water-cooled chillers, heat recovery ventilation units and rooftop packages to distributors and contractors in more than 80 countries. The company operates 12 automated production lines with annual capacity above 500,000 sets, and holds CE, Eurovent, TUV SUD, SASO, ESMA, GCC and ISO 9001, 14001 and 45001 certifications. Products are T3 rated for operation up to 55 degrees Celsius, and shipments are made FOB Ningbo and Shanghai.

 

For refrigerant and GWP confirmation on a specific model, contact our export team with the destination country and the capacity range.